Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Sci Monit ; 30: e943502, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38515376

RESUMO

BACKGROUND Modification of the glass fiber post (GFP) with titanium dioxide or silver particles can improve the durability and reliability of dental treatments for ensuring long-term success. This research assessed the tensile bond strength (TBS) of an adhesive system used for cementing GFPs into root dentin following the incorporation of nanoparticles of titanium dioxide (NTiO2) and silver (NAg). MATERIAL AND METHODS Sixty human maxillary canines were prepared to create a 10-mm intra-radicular space for post placement from the cementoenamel junction. The specimens were randomly allocated into 2 groups (a non-thermocycling group and a thermocycling group). Each group was divided into 3 subgroups (10 samples each) according to the adhesive system used (adhesive system devoid of any addition, adhesive system including 1% NAg, and adhesive system infused with 1% NTiO2). TBS tests were conducted and recorded in MPa using a Universal Testing Machine, with an axial load applied at a rate of 0.5 mm/min until failure. The TBS for both groups (non-thermocycling and thermocycling) was measured in megapascals (MPa), and the failure type was recorded. The data were statistically analyzed using one-way analysis of variance (ANOVA) and Tukey's test with P.


Assuntos
Adesivos , Colagem Dentária , Vidro , Titânio , Humanos , Cimentos de Resina/química , Resistência à Tração , Reprodutibilidade dos Testes , Prata , Dentina , Teste de Materiais
2.
Medicina (Kaunas) ; 59(11)2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-38003997

RESUMO

Background and Objectives: This review focuses on reviewing studies from the literature regarding the effects of deep margin elevation on the surrounding periodontium. Materials and Methods: A review of the literature was carried out using the following online databases: Embase, The Cochrane Library, MEDLINE-PubMed and Google Scholar. Our search was limited to articles from 2010 to 2023. The search terms consisted of keywords and MeSH terms, which were 'deep margin elevation', 'coronal margin relocation', 'periodontium' and 'periodontal tissues'. The literature was searched thoroughly by two reviewers. Initially, the titles of the articles were extracted. After removing irrelevant and duplicate articles, abstracts were assessed for relevant articles. Finally, the reviewers analyzed full-text articles. Results: A total of twelve articles, including one randomized clinical trial, three systematic reviews, two prospective cohort, three case series, one a clinical study, one pilot study and one a retrospective study, were selected and analyzed. Conclusions: The review suggests potential benefits of Deep Margin Elevation (DME) over surgical crown lengthening due to reduced invasiveness, yet conclusive effects on periodontal tissue remain unclear, warranting further studies on clinical parameters and inflammatory biomarkers.


Assuntos
Ligamento Periodontal , Periodonto , Humanos , Estudos Prospectivos , Projetos Piloto , Estudos Retrospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto
3.
Med Sci Monit ; 28: e938354, 2022 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-36320129

RESUMO

BACKGROUND The aim of this study was to assess and compare the effect of surface type (glazed or polished) with coffee immersion and aging on surface topography (Ra), optical properties (TP, OP), and mechanical properties (fracture forces and modes) of zirconia-reinforced lithium silicate (Vita Suprinity), hybrid polymer-infiltrated-feldspathic ceramic network material (Vita Enamic), and leucite-containing feldspathic glass (Vitablocs® Mark II) made by computer-aided design and computer-aided manufactured (CAD/CAM) ceramic materials. MATERIAL AND METHODS Fifty-four specimens were assembled out of the above 3 CAD/CAMs ceramic materials. Each group was divided into glazed or polished surfaces, having 9 specimens of every type and stained in coffee for 15 days. Ra and color of specimens in the form of TP and OP were recorded before and after immersion in staining material. Fracture forces and modes were analyzed after the 90-day aging. Data were analyzed using ANOVA, then post hoc analysis and Bonferroni tests. RESULTS Our study found significant differences in Ra, TP, and Op before and after coffee immersion between glazed and polished specimens, with higher values in the polished surfaces among the 3 ceramic materials. The highest values of fracture resistance were noted in Vita Suprinity, and Vita Enamic had the lowest values, without significant differences among groups. CONCLUSIONS Most of the TP and OP values were in acceptable clinical range, and Vita Suprinity had superior TP than the other groups. Reparable fracture types were observed in Vita Suprinity, whereas semi-reparable and non-reparable were predominant in other groups.


Assuntos
Café , Imersão , Teste de Materiais , Propriedades de Superfície , Cerâmica , Porcelana Dentária
4.
Materials (Basel) ; 15(16)2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36013880

RESUMO

Resin-bonded fixed dental prostheses (RBFDP) are minimally invasive alternatives to traditional full-coverage fixed partial dentures as they rely on resin cements for retention. This study compared and evaluated the tensile bond strength of three different resin-bonded bridge designs, namely, three-unit fixed-fixed, two-unit cantilever single abutment, and three-unit cantilever double-abutted resin-bonded bridge. Furthermore, the study attempted to compare the tensile bond strengths of the Maryland and Rochette types of resin-bonded bridges. Based on the inclusion and exclusion criteria, a total of seventy-five extracted maxillary incisors were collected and later were mounted on the acrylic blocks. Three distinct resin-bonded metal frameworks were designed: three-unit fixed-fixed (n = 30), two-unit cantilever single abutment (n = 30), and a three-unit cantilever double abutment (n = 30). The main groups were further divided into two subgroups based on the retainer design such as Rochette and Maryland. The different prosthesis designs were cemented to the prepared teeth. Later, abutment preparations were made on all specimens keeping the preparation as minimally invasive and esthetic oriented. Impression of the preparations were made using polyvinyl siloxane impression material, followed by pouring cast using die stone. A U-shaped handle of 1.5 mm diameter sprue wax with a 3 mm hole in between was attached to the occlusal surface of each pattern. The wax patterns were sprued and cast in a cobalt-chromium alloy. The castings were cleaned by sandblasting, followed by finishing and polishing. Lastly, based on the study group, specimens for Rochette bridge were perforated to provide mechanical retention between resin cement and metal, whereas the remaining 15 specimens were sandblasted on the palatal side to provide mechanical retention (Maryland bridge). In order to evaluate the tensile bond strength, the specimens were subjected to tensile forces on a universal testing machine with a uniform crosshead speed. The fixed-fixed partial prosthesis proved superior to both cantilever designs, whereas the single abutment cantilever design showed the lowest tensile bond strength. Maryland bridges uniformly showed higher bond strengths across all framework designs. Within the limitations of this study, the three-unit fixed-fixed design and Maryland bridges had greater bond strengths, implying that they may demonstrate lower clinical failure than cantilever designs and Rochette bridges.

5.
Med Sci Monit ; 28: e936892, 2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35711131

RESUMO

BACKGROUND Miswak is a form of chewing stick used to clean teeth in different parts of the world, including Saudi Arabia. We present a description of the effects of miswak derivatives, namely toothpaste, mouthwash, and brushing sticks, on the mean color changes (DE00), compressive fracture resistance values, and fracture modes of polymer-based computer-aided design (CAD) and computer-aided manufactured (CAM) prosthetic materials. MATERIAL AND METHODS Eighty-one rectangular-shaped samples were prepared from lithium disilicate glass-ceramic (IPS e.max CAD), zirconia-reinforced lithium silicate (Vita Suprinity), and monochromatic tooth-colored feldspar (Vitablocs Mark II) CAD/CAM ceramics. The color parameters were recorded using spectrophotometer before and after exposing the specimens to the different miswak oral hygiene derivatives for 15 days. Compressive fracture resistance values and fracture types were also assessed, and statistical analysis was performed. RESULTS Vita Suprinity and Vitablocs Mark II miswak sticks had the highest ΔE00 values. Moreover, miswak mouthwash had the lowest ΔE00 values, with significant differences among groups. IPS e.max CAD miswak sticks had the highest mean values of compressive fracture. Vitablocs Mark II had the lowest values for mouthwash and toothpaste. Significant differences were found within the IPS e.max CAD group. Reparable fractures were found in IPS e.max CAD, while semi-reparable fractures were seen in other groups. CONCLUSIONS Most ΔE00 values were within the acceptable clinical range, with IPS e.max CAD showing superior color stability. The mouthwash group showed minimal ΔE00. IPS e.max CAD had the highest mean compressive fracture resistance values with reparable fracture types.


Assuntos
Antissépticos Bucais , Polímeros , Cerâmica , Cor , Desenho Assistido por Computador , Computadores , Porcelana Dentária , Teste de Materiais , Antissépticos Bucais/farmacologia , Propriedades de Superfície , Cremes Dentais
6.
Materials (Basel) ; 15(11)2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35683165

RESUMO

CAD/CAM technology is gaining popularity and replacing archaic conventional procedures for fabricating dentures. CAD/CAM supports using a digital workflow reduce the number of visits, chair time, and laboratory time, making it attractive to patients. This study aimed to provide a comparative review of complete dentures manufactured using CAD/CAM and conventional methods. The PubMed/Medline, Science Direct, Cochrane, and Google Scholar databases were searched for studies published in English within the last 11 years (from 2011 to 2021). The keywords used were "computer-engineered complete dentures", "CAD/CAM complete dentures", "computer-aided engineering complete dentures", and "digital complete dentures". The search yielded 102 articles. Eighteen relevant articles were included in this review. Overall, computer-engineered complete dentures have several advantages over conventional dentures. Patients reported greater satisfaction with computer-engineered complete dentures (CECDs) due to better fit, reduced chair time, shorter appointments, and fewer post-insertion visits. CAD/CAM allows for precision and reproducibility with fewer procedures compared to conventional dentures. Polymethyl methacrylate is used as the denture base material for conventional dentures. For CECDs, the resin can be modified and cross-linked to improve its mechanical properties. The advantages of CECDs include a reduced number of appointments, saving chairside time, a digital workflow allowing easy reproducibility and greater patient satisfaction with a better fit.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...